Can we (does the code allow for it)? Will it make realistic perception? Are there pitfalls as a result of our local weather? How may well we have to change that to fit it to out predicament?

Try to remember, an insulated sloped ceiling isn’t constantly a good idea. From time to time a superb outdated-fashioned unconditioned attic is the best way to cap your house.

Your caveat is suitable and conservative. For that overwhelming majority of builders, nonetheless, the code demands will retain roofs free of challenges.

sips are excellent but during the coldest of climates they may have encountered troubles. google issue apps in alaska - apparently a group of properties there were built although not sufficient notice to element for that plumbing and roof vents have been taken under consideration (Certainly air restricted foamed in penetrations), mated panel seams and fastener punctures prompted the highest level osb to rot. As you can imagine The complete roofs necessary substitution.

Will it sound right to spray and cut and cobble four inch closed mobile foam/board on underside of sheathing accompanied by fiberglass Within the bays and one inch of eps/iso under the rafter (to stop thermal bridging) prior to ending with drywall? Will I develop a vapor sandwich and superior leave the ultimate EPS and settle for the thermal bridging?

Ideally, you wish to have an airtight barrier over and underneath your fiberglass batts. If you can realize These two air barriers, then wind-washing is just not an issue in a roof like yours. (It can be inside a vented unconditioned attic, needless to say, Primarily near the soffits.)

1. You need to get an engineer To judge the safety of one's 2x4 rafters. "Furring down with 2x2s" does not Enhance the ability of your respective 2x4s to bear the snow load. It is really attainable that an engineer will recommend you to definitely sister 2x8s or 2x10s on to your existing 2x4 rafters.

If you wish to install a combination of shut-cell spray-foam to the underside of the roof sheathing and air-permeable insulation amongst your rafters — an approach often referred to as “flash and batt” — the making code demands that spray foam (or, arguably, rigid foam insulation) be “applied in direct Get hold of with the underside of the structural roof sheathing” and that the foam insulation fulfill the requirements “specified in Table R806.

Martin, re: changing the attic more than the next Tale bedrooms into a conditioned attic and sealing the soffit vents.... Previous to this most recent strategy about insulating with rigid foam in addition to the cathedral ceiling, we had been planning to cut a ridge vent in the gable ridge, in order to meet up with ventilation code needs. Presently Now we have eave vents additionally two relatively useless gable vents, 1 on each side.

It's a code violation to setup an air-permeable insulation like fiberglass batts amongst unvented rafters. It's also a nasty thought, due to the fact humidity can accumulate on your own roof sheathing see this website if you are trying this method, roofing company owner salary and you may wind up with sheathing rot.

Martin, many thanks. I just talked into the roofer and he rejected the thought of only putting the foam about the relatives place cathedral ceiling. That Odd "jog" from the roofline, possessing it abruptly bump up four" or eight" the place the family members room starts, in the middle of the back facet of your roof, would defeat roofing company owner salary the concept of a constant slope for rain to come down when it hits the upper Component of that back again roof. Hence the four" or eight" height addition requirements to continue throughout the full 2nd story roof line.

I are actually using rigid breadboard fashion expanded polystyrene in the rim joists and considered the exact same might be place underneath the sheathing in between the rafter bays, and with any gaps sealed with a urethane spray foam for instance Fill and Seal. Is there a quality that makes spray foam acceptable and rigid foam unacceptable?

A. The air barrier can be a vapor barrier, since the rigid foam is also more likely to be described as a vapor barrier (or near to it) in almost any case.